Rotary Drilling Rig 6D24 Engine Cranked but Would Not Start: Tracing a Failed K6 ECU Power Relay

A cranking engine can still have an electrical no-start fault. When the starter turns but fuel is not delivered at the injectors, technicians often begin with the fuel path, air in the pump and the injection-pump mechanism. Those checks are necessary, but they do not confirm that the engine control and internal throttle actuator have electrical power.
This anonymized training case records the same symptom on more than one 280-class rotary drilling rig equipped with a Mitsubishi 6D24 engine. The field note documents the sequence of checks, one missing 24 V feed and the engine restart after power and relay function were restored. It does not provide a public rig model, equipment number, production year, operating hours, fault code or long-term repair record.
The Starter Turned, but the Injectors Did Not Deliver Fuel
The reported symptom was specific: the starter motor rotated the Mitsubishi 6D24 engine, but no fuel was observed at the injectors and the engine would not start. That pattern separated the complaint from a completely dead starting circuit, because battery and starter energy were sufficient to crank the engine.
The archive notes that similar symptoms appeared on more than one 280-class rig, but it does not identify a public serial number or exact machine configuration. The article therefore retains the engine family and broad machine class without assigning an unrecorded SR model, year or hour reading.
For a buyer, a cranking video alone is not acceptance evidence. The inspection should show cranking speed, warning indicators, fuel delivery, supply voltage and the final start. Repeated attempts without a structured check can overheat the starter and discharge the batteries while leaving the actual fault untouched.
- Confirmed symptom: the 6D24 engine cranked but did not start.
- The source records no fuel delivery at the injectors.
- The exact rig model, year, hours and equipment number are not public evidence.
- Starter rotation did not prove the ECU power path was healthy.
Initial Checks Stayed on the Fuel and Pump Side
The field sequence first considered a restricted diesel line, air trapped in the injection pump and a stuck or damaged variable mechanism at the end of the injection pump. Those checks followed the visible symptom: the engine turned but fuel did not reach the injectors.
The engine still would not start after those items were investigated. That negative result was useful because it prevented the team from treating fuel-line service as a successful repair. The source does not provide fuel-pressure measurements, bleed volume, filter condition or photographs of the pump internals, so none of those items can be declared fully verified from the archive.
A disciplined no-start diagnosis should preserve the order of evidence. Confirm fuel supply and air removal, but also verify that the engine-control circuit is powered before disassembling the injection system. This is especially important when an electronically controlled throttle or shutoff mechanism is built into the pump.
- Fuel-line restriction and trapped air were considered first.
- The injection-pump end mechanism was also checked.
- Those steps did not restore starting in the recorded case.
- No fuel-pressure or pump-internal measurement is preserved.
The Diagnosis Moved to the K6 ECU Power Relay
The investigation then moved to the electrical control system. In the source, K6 is identified as the ECU power relay. A failed K6 circuit could prevent the internal throttle actuator at the injection pump from operating even though the starter motor continued to crank the engine.
The archived procedure checked the K6 relay socket and related wire numbers 80, 81 and 44. The decisive observation was that wire 81 had no voltage. The source states that wires 81 and 44 were 24 V supply circuits in this installation, so the missing voltage explained why the pump-end actuator was not working.
Wire numbers and relay functions can differ across machine versions. An inspector should not bridge terminals based only on a historical case. Confirm the exact schematic, relay rating, fuse protection and ground path first, then measure the circuit with an approved meter and breakout method.
- K6 was identified as the ECU power relay in the supplied case.
- Wire 81 was measured with no voltage.
- The source identifies wires 81 and 44 as 24 V supplies in that installation.
- Historical wire numbers must not replace the exact machine schematic.
Restoring Power and Using a Known-Good Relay Allowed the Engine to Start
The field record states that 24 V supply was restored to the wire 81 path and that the K6 relay was also found defective. A known-good relay was used in the K6 position. After those actions, the 6D24 engine started successfully.
That result links the no-start symptom to the ECU power path, but the archive does not document a permanent harness repair, a new relay part number, voltage-drop readings or an extended restart test. The intervention described in the training material should therefore be reported as the observed field result, not as a complete modern repair instruction.
The supplied photograph shows the relay area and its wire labels. It is useful for understanding the inspected location, but it does not prove internal relay damage or the quality of a final wiring repair. A buyer should ask for photographs after the permanent repair and a continuous cold-start and warm-restart demonstration.
- The source restored 24 V to the wire 81 path.
- A known-good K6 relay was fitted for the successful start.
- The engine then started according to the field record.
- The permanent harness repair and long-term repair result are not documented.
What a Buyer Should Verify After an Electrical No-Start Repair
Request the exact wiring diagram and a voltage-drop record across the battery, ignition supply, K6 relay contacts and engine-control feed during cranking. A static 24 V reading without load may miss a high-resistance connector or damaged relay contact. Fuse rating and relay rating should match the machine documentation.
The acceptance video should show a cold start, stable idle, speed increase, shutdown and warm restart. Ask for the replaced relay part number and close photographs of the socket and repaired wiring. If a temporary jumper or substitute relay was used during diagnosis, require its removal and a documented permanent repair before shipment.
Kepler Machinery uses this case to show why a cranking engine still needs an electrical power check. The visible symptom pointed toward fuel delivery, but the missing voltage on wire 81 and the K6 relay result provided the evidence that changed the diagnosis.
- Measure the ECU power path under cranking load, not only with the key on.
- Verify fuse, relay and wire ratings against the exact schematic.
- Remove diagnostic jumpers and document the permanent repair.
- Require cold-start and warm-restart evidence before acceptance.
Cranking Did Not Prove ECU Power Was Available
The supplied case moved from fuel-system checks to the K6 ECU power path after the 6D24 engine continued to crank without injector delivery. Finding no voltage on wire 81, restoring the supply and fitting a known-good K6 relay allowed the engine to start.
The archive confirms that field result but not the permanent wiring repair or long-term acceptance. A buyer should therefore request load-tested voltage evidence, the final relay and harness condition, and repeated start results before treating the repair as complete.
Safety Note
Starting-circuit diagnosis involves high current, rotating components, hot engine parts and the possibility of unexpected starting. Only qualified personnel should test the machine using the exact wiring diagram. Secure the rig, keep personnel clear of moving parts, use fused and rated test equipment, and never leave a diagnostic jumper or substitute relay as an undocumented permanent repair.