Rotary Drilling Rig Had No Depth Reading: Finding a Collision-Damaged Proximity Switch

A missing drilling-depth reading is easy to label as an electronic failure. The display, controller, harness, and sensor can all produce a similar complaint, but the root cause may be visible before any module is replaced. On a used rotary drilling rig, mast wiring and sensor guards also face vibration, dirt, and impact exposure during transport and site work.
This field case began with no depth reading on the operator display. The service team checked the controller-to-display path, traced the mast wiring, and then lowered the mast for a closer physical inspection. The proximity-switch guard was deformed by an impact, and the sensor probe was suspected of being damaged. Replacing the proximity switch restored the depth indication.
The Display Had No Depth Reading
The reported symptom was specific: the operator display did not show drilling depth. The source did not record a reliable public model, year, operating hours, or equipment number, so none is inferred here. The useful starting point is the missing measurement itself and the need to separate a display problem from a lost sensor signal.
A depth system needs more than a working screen. The controller must receive the sensor transitions, the mast harness must carry the signal, and the display must receive processed data. A failure anywhere in that chain can remove the reading, while an intermittent connection may make the value jump or disappear only as the mast moves.
For a buyer, the first record should show the display before any reset or part replacement. Operate the relevant mechanism only under controlled conditions and record whether the value is blank, fixed, intermittent, or moving in the wrong direction. Those differences guide the next inspection.
- Confirmed symptom: no drilling-depth reading appeared on the display.
- Initial fault groups: display, controller, wiring, or proximity switch.
- No unsupported model, year, hour, or location detail is added.
- The inspection preserved the symptom before replacing components.
The Fault Domain Included Electronics and Exposed Mast Hardware
The source report listed four practical possibilities: a wiring fault, a display problem, a controller problem, or a failed proximity switch. That list covered the complete signal path without assuming that the most expensive component had failed.
The controller-to-display wiring was checked first and did not reveal the fault described in the complaint. This result did not prove that every electronic component was perfect, but it reduced the case for replacing the controller or display without further evidence.
The inspection then followed the wiring toward the mast and the proximity-switch area. This direction matters on used equipment because the mast sensor hardware sits in a mechanically exposed zone. A connector may be electrically sound while the bracket, guard, or sensor face has been struck.
- Controller and display were treated as possibilities, not assumptions.
- The controller-to-display wiring check did not reveal a fault.
- The diagnostic path moved toward the mast harness and sensor area.
- Mechanical exposure remained part of the electrical diagnosis.
Lowering the Mast Exposed the Damaged Guard
The technicians traced the wiring along the mast and lowered the mast so the sensor area could be inspected closely. The guard around the proximity switch was deformed after an impact. The physical damage gave the first direct explanation for why the depth signal had disappeared.
A damaged guard does not automatically prove that the sensor has failed, but it changes the inspection priority. The source team suspected that the same impact had damaged the proximity-switch probe. That finding connected an external event to the missing electronic signal without requiring an unsupported controller diagnosis.
On an export inspection, photograph the guard from several angles and check sensor clearance, cable strain, connector locking, and nearby contact marks. A clean static photograph is not enough when the gap changes through mast movement. The goal is to show that the sensor and target remain protected and correctly aligned throughout the relevant range.
- The mast wiring was followed to the proximity-switch area.
- The mast was lowered for direct physical inspection.
- The sensor guard was visibly deformed by an impact.
- The impact made sensor-probe damage the supported next diagnosis.

Replacing the Proximity Switch Restored the Depth Display
The damaged proximity switch was replaced. After replacement, the display again showed drilling depth, confirming that the missing signal came from the sensor area rather than the controller-to-display wiring that had already passed inspection.
The repair result also explains why visual inspection mattered. Replacing the screen or controller would not have corrected a sensor damaged by collision. The deformed guard was not cosmetic damage; it was evidence that the protected sensing component had experienced an external load.
The source report confirms restored display operation but does not provide a full calibration record or accuracy check over the complete drilling range. Those results are not invented. A stronger delivery test would verify zero reference, direction, repeatability, and depth change through controlled movement after the new switch is installed.
- Corrective action: replace the impacted proximity switch.
- Recorded result: replacing the proximity switch restored the depth reading.
- The repair connected the physical impact evidence to the lost signal.
- Recommended follow-up: verify direction, repeatability, and calibration.

What a Used-Rig Buyer Should Request
Ask the seller to show the depth value before movement, during a controlled change, and after returning to the reference position. The video should include the relevant mast sensor area as well as the display. This makes it easier to connect a stable mechanical target and sensor gap with the displayed measurement.
Inspect sensor guards as functional protection, not paintwork. Bent plates, fresh welds, crushed cable conduit, loose brackets, and contact marks can reveal prior impact even when the display works during a brief test. A repaired guard should keep the sensor aligned and shielded without restricting normal motion.
Kepler Machinery uses this evidence chain when evaluating used rotary drilling rigs: preserve the symptom, check the signal path, inspect exposed hardware, replace the component supported by the evidence, and confirm the function after repair.
- Request one continuous video showing both movement and the depth value.
- Inspect the guard, sensor gap, bracket, cable, and connector condition.
- Confirm that the reading changes in the correct direction and returns consistently.
- Keep before-and-after photographs with the inspection record.
Mechanical Damage Can Look Electronic
The missing depth reading was not traced to the display or controller by assumption. The controller-to-display wiring check did not reveal the fault, and following the mast harness led to a deformed sensor guard. The impact evidence justified inspection of the proximity switch itself.
Replacing the damaged switch restored the depth indication. For an overseas buyer, the lesson is practical: exposed sensor hardware and its protective structure belong in the functional inspection, because mechanical damage can present as an electronic complaint.
Safety Note
Depth-sensor diagnosis may require mast movement and access near heavy structures. Only qualified personnel should perform the inspection. Follow the machine-specific service procedure, lower or securely support the mast, isolate electrical power where required, release stored energy, and keep personnel outside the machine's movement and pinch zones.